Sewer & drain lining techniques
Over 225mm diameter
The following techniques all have variants that can be used in pipes over 225mm diameter. Their suitability and applicability will depend on issues such as the time available on site, the available site footprint for equipment, the hydraulic capacity of the pipe, the loadings that will occur, man hole availability and size, bend direction and degree, required service life and budget restraints.
With the larger liners, their weight and handling requirements make ambient techniques very difficult in practice.
Potential CIPP techniques
Ambient cure silicate resin patch repair
Hot water cure polyester resin liners
Steam cure polyester resin liners
Hot water cure epoxy resin liners
Stream cure epoxy resin liners